An RL high-pass filter consists of a 470 Ω resistor and a 600 mH coil. The output is taken across the coil. The circuit’s critical frequency is-
- 125 Hz
- 1,250 Hz
- 564 Hz
- 5,644 Hz
Answer: A. 125 Hz
An RL high-pass filter consists of a 470 Ω resistor and a 600 mH coil. The output is taken across the coil. The circuit’s critical frequency is 125 Hz.
Solution
Filter consists of-
Resistor (R) = 470 Ω
Inductance (L) = 600 mH
At critical frequency,
XL=R
2fπL=R
f=R/2πL
f=470/(2×π×600×10-3)
f=125 Hz