Question 1

For salient pole alternator, consider the following: Xd = 1 p.u., Xq = 0.6 p.u. At full load 0.8 p.f., load angle in degrees. (Use tan–1(1.5) = 56.3°).

Question 2

A continuous random variable has following density function given as:

The mean of this random variable is _________.

Question 3

A cable has the following characteristics:

L = 0.2

The velocity of wave propagation through the cable is

Question 4

The impulse response of a continuous time system is given by h(t) = δ(t-1) + δ(t-3). The value of the step response at t=2 is

Question 5

If the length of the cable is halved, what will be the effect on capacitance C will be_________?

Question 6

The power transformer having capacity of 5 MVA with 66/33 kV (delta-star) is protected by circulating current protection system. The ratio on primary side and secondary side of the transformer respectively for a circulating current of 5 A in the pilot wire is ________

Question 7

Power MOSFET is a ________ device.

Question 8

The dielectric loss in the insulation of a lossy underground cable due to leakage current is

Question 9

What is the true fact regarding Ward-Leonard System of Speed Control of DC motor?

Question 10

A 1 mA meter is to be converted into 0 – 100 mA range. If internal resistance is 100 Ω then value of shunt resistance received is _______Ω.

Question 11

Which of the following coupling can be used for the amplification of DC and very low frequency ?

Question 12

A sinusoidal voltage of amplitude 50 V is applied to a half wave rectifier having forward resistance of 6 Ω. A hot wire and PMMC instruments are connected in the circuit for measurement of current. The readings of hot wire and PMMC instruments are

Question 13

Consider two synchronous generators defined by

P1 = 100(50 – f) in MW

P2 = 50(51 – f) in MW

Where, f is _______Hz if total load is 500 MW. (Consider system to be lossless)

Question 14

A star connected load is supplied by a 50 Hz source. The rating of load is 20 KVA, 0.8 pf lagging. If the receiving end voltage is 400 V then what is the per phase capacitance of delta connected bank required to bring power factor to unity?

Question 15

The starting current in an induction motor is 5 times the full-load current while the full load slip is 4%. The ratio of starting torque to full load torque is