Answer: Option A
The centrifugal pump discharge formula is Q = π.D.B.Vf
Solution:
The discharge of a centrifugal pump is the product of the flow area of the pump and flow velocity. It is given as;
Q = Flow area at inlet x flow velocity at inlet = Flow area at outlet x flow velocity at the outlet
Q = A1.Vf1=A2.Vf2
Q = π.D1.B1.Vf1=.D2.B2.Vf2
Where;
- D1 and D2 = Diameter of the impeller at inlet and outlet.
- B1 and B2 = Width of the impeller at inlet and outlet
- Vf1 and Vf2 = Flow velocity and inlet and outlet.
Hence, the centrifugal pump discharge formula is Q = π.D.B.Vf