Load Carrying Web Stiffeners Should Be Provided Where
By BYJU'S Exam Prep
Updated on: September 25th, 2023
Load carrying web stiffeners should be provided where a concentrated load, which exceeds x per cent of the shear capacity of the member, is applied within D/2 of a plastic hinge location. What is x?
- 20
- 25
- 15
- 10
Answer: D. 10
Load carrying web stiffeners should be provided where a concentrated load, which exceeds 10 per cent of the shear capacity of the member, is applied within D/2 of a plastic hinge location.
Solution
As per clause 4.5.2.2 of IS 800:2007,
Web stiffeners should be provided where a concentrated load , which exceeds 10 percent of the shear capacity of the member, is applied within D/2 of a plastic hinge. Load carrying web stiffeners should be provided within a distance D/2 (half of the depth of the member) on either side of the hinge location.